Home

Alginate impressions must be poured within

Alginate Heute bestellen, versandkostenfrei An alginate impression should be removed from the mouth with a quick continuous motion to minimize: Permanent distortion. Most alginate impressions must be poured within _____ so that distortion does not occur. 1 hour. The length or depth of the impression tray borders can be extended by Alginate impressions must be poured within _____ so that distortion does not occur. 1 hour. What term is used when an alginate impression takes up water either from soaking or wrapping in a wet paper towel? Imbibition. Which type of impression tray covers the anterior portion of the dental arch Most alginate impressions must be poured within _ so that distortion does not occur. a. 5 minutes b. 30 minutes c. hour d. 24 hours. c. hour. If an alginate impression is stored in water or in a soaked paper towel, the alginate will absorb the additional water and expand. This property is called _ . a. Syneresi An impression tray should be sufficiently deep to allow ___ mm of material between the tray and the incisal/occlusal edges of the teeth : 2 - 3 mm: The irreversible hydrocolloid material used most widely for preliminary impressions is: alginate: most alginate impressions must be poured within _____ so that distortion does not occur: 1 hou

Alginate impressions must be poured within _____ so that distortion does not occur. 1 hour. How are alginate impressions removed from the mouth? Use one quick, snap-out motion. What term is used when an alginate impression takes up water either from soaking or wrapping in a wet paper towel alginate impressions must be poured within __so that distortion does not occur. 1 hour. which of the following is not correct regarding reversible hydrocolloids? the material is 85% agar and 15% water. how is the impression tray prepared for an elastomeric impression? coated with adhesive

The decades-old tenet that alginate impression materials must be poured immediately and never be immersed in a liquid, wrapped in a damp towel or stored before casting in gypsum no longer may be valid for every alginate impression material if stored adequately for limited times - Other uses require very exact (within 0.1%) - There fore, alginate is an acceptable impression ma terial for study models, but it is an unacc eptable impression material for the fabrication of bridges, - Condensati on silicone impressions must be poured without delay 42. Alginate impressions must be poured within _____ to minimize distortion and preserve accuracy. A. one hour B. 24 hours C. 45 minutes D. 30 minutes E. 10 minutes 43. A set impression of alginate is _____ percent water. (by weight) A. 20 B. 40 C. 60 D. 80 E. 90 44. The most important property of a dental restorative material is Most alginate impressions must be poured within _____ so that distortion does not occur. 1 hour. alginate material not setting or setting too rapidly may be the result of. expired shelf life humidity improper storage. Criteria for an acceptable alginate impression include all of the following except

Alginate - Alginate Restposte

  1. Most alginate impressions must be poured within ___ so that distortion does not occur. 1 hour. 500. Presentation of the treatment plan ___. Should be done in terms the patient will understand 500. When is tooth whitenening or vital bleaching not indicated for a dental patient
  2. after the impression is removed from the patient's mouth. Dahl et al., concluded that clinically acceptable working casts could be obtained from irreversible hydrocolloid impressions poured even after 3 h
  3. Alginate impression material begins as a powder. When mixed with water, a thick pasty material, similar to cake frosting, appears. The dental impression tray is filled with the viscous alginate impression material and placed over the teeth, one arch at a time. The alginate impression material sets after 30 to 60 seconds in the patient's mouth
  4. ary impression? A: alginate What is the term used when an alginate impression takes up water from soaking or wrapping in a wet paper towel? A: imbibition Which of the following is utilized to extend the length.

Chapter1 Study impressions Flashcards Quizle

  1. utes with dental stone within 10 seconds and after 45
  2. utes for best results
  3. ary impressions?-Alginate 7. Alginate impressions must be poured within _____ so that distortion does not occur. - 1 hou
  4. utes [8,9]. It has also been reported that extended-pour alginate impressions can be maintained for up to five days [2] with small dimensional changes, which ar
Impressions and physiologic adjustment

Chapter 46 quiz Flashcards Quizle

Alginate impressions must be poured within _____ so that distortion does not occur. An understanding of the methods and mechanics of sterilization and disinfection is necessary to prevent bacterial cross-contamination. Unfortunately a lot of the impression materials currently in use, especially alginate and polyether impression materials, are. The reaction that causes an alginate impression to set is: Na alginate + CaSO 4 (mixed with water) -> Ca alginate + Na 2 SO 4 (forming a gel with water). One can accelerate the setting reaction by adding more Ca-ions. Therefore, to slow down the reaction initially, the alginate powder contains Na 3 PO 4.The PO 4-ions from that powder reacts immediately with the Ca-ions from the CaSO 4 as soon. Most alginate impressions must be poured within ____ so that distortion does not occur. 1 hour If an alginate impression is stored in water or in a soaked paper towel, the alginate will absorb the additional water and expand an alginate impression material that is mixed to a sol state and as it sets converts to a gel by a chemical reaction that irreversibly changes its nature. Impressions taken with polyether should be poured within: 1 week . the material poured into the impression must reach the initial set before the base is poured 1. Make impressions of upper and lower arches using custom trays. Care should be taken to capture the complete palate as well as vestibules. If using alginate or hydrocolloid, the impressions must be poured within five minutes to ensure accuracy. (Fig. 1) 2. Record a bite registration using a rigid bite registration material. 3

that casts produced from alginate impressions must be generated immediately or within 12 min-utes after the impression is removed from the patient's mouth.1-12 Researchers have recom-mended immediate pouring of a gypsum product into the impression because there is no adequate storage method for any hydrocolloid impression Question 9 The atmosphere that is best for storing impressions is ____ percent relative humidity. 70 10 45 100 Question 10 What may be done to alleviate the gag reflex when taking alginate impressions? Use fast-set alginate, as it allows the impression tray to be removed from the mouth much sooner than if using normal set alginate Also, alginate impression can dry and shrink causing distortions in the material. These distortions can lead to appliances that don't fit or misdiagnosis if the impression is used to make a study model. The threat of distortion means that alginate impressions must be poured-up much more quickly than a PVS impression 1. Make impressions of upper and lower arches using custom trays. Care should be taken to capture the complete palate as well as vestibules. If using alginate or hydrocolloid, the impressions must be poured within five minutes to ensure accuracy. 2. Record a bite registration using a rigid bite registration material. 3

masseter

6 WB # 5: Chapter 46: Impression Materials Flashcards

If the impression must be stored until it can be poured a few hours later, it must be kept in 100% humidity (as with the damp towel and zippered plastic bag). Tear Strength The tear strength of alginate is more important than its compressive strength, because most commercial alginates far exceed the minimum allowable value for compressive strength Fig. 2-3. A to C, Making an alginate impression for diagnostic casts. surface detail due to the disinfection procedure. 5,6 To ensure accuracy, pouring should be completed within 15 minutes of the time the impression is removed from the mouth. Keeping an impression in a moist towel is no substitute for pouring within the specified time Some studies 8-12 recommend that alginate impressions must be poured as fastest as possible, avoiding the excessive air exposure (syneresis and evaporation). If the pouring procedure is not possible, the most recommended step is to keep the impression at 100% humidity environment in order to preserve the hydric balance within the material 13. and therefore impressions must be poured immediately (alginates) or at least within a few hours (c-silicones). A study compared leading brands of impression materials, rating them on four clinically relevant properties. Values for each property ranged from 1 = poor to 10 = excellent. Source: 3M ESPE Silagum® Light (VPS) Express. The disinfection of alginate impressions must be carried out with regard for the dimensional instability of the impression material. Fluid at the time it is poured into the impression so that fine detail can be recorded. There is residual stress within the baseplate wax that holds and surrounds the teeth of a wax denture pattern

(Q1) CDPR 5001: Lecture Highlights Flashcards | Quizlet

Irreversible hydrocolloid impressions should generally be poured immediately or within 12 min when stored in 100% humidity at room temperature. To evaluate the potential of chitosan after the usual time lapse of 10 min, in the present study, the microbial CFUs were estimated at the time intervals of 0, 10, and 20 min to evaluate the passage of. therefore impressions must be poured immediately (alginates) or at least within a few hours (c-silicones). Alginate C-Silicone Express™ XT (e.g., Speedex) VPS Wash Material Dimensional stability - - 4 Very high tensile strength - - 4 Multiple pouring - 4 4 Long-term storage - - 4 Hydrophilicity 4 4 4 Automatic mixing - - 4 After 24 hours, the. Even under proper storage conditions the cast should be poured within an hour. The impression should not be wrapped too tightly which incorporates stress. The disinfection of alginate impressions must be carried out with regard for the dimensional instability of the impression material. Remove the alginate impression from the damp paper. All students MUST review pre-clinical and year 3 course notes prior to performing procedures from clinic and laboratory. 2. ALGINATE. impressions . cannot be boxed and must be separated from cast not later than one hour from being poured. 3. Infection control: All impressions, appliances, etc. must be sprayed - not submerged

Free Dentistry Flashcards about Chapter 46 im

The impressions must be scanned within 24 hours to prevent dimensional changes that lead to errors. • Digital models and plaster casts can be obtained from 1 impression with a CBCT scanner to scan an alginate impression Alginate <br />Gelation reaction-<br /> 2Na3P04 + 3CaSo4----- Ca3(Po4)2+3 Na2SO4<br /> is one of the least stiff or highly flexible of elastomeric material<br /> For accurate polysulfide impressions-<br />The cast should be poured immediately after taking impression<br />Minimise the amount of material used to take impression by using. the impression cannot be poured at once, the impression must be held in a moist environment (sealed plastic bag) until it can be poured. Alginates should be poured within 30 minutes for best results. If this is not possible, it can be stored in a holding solution, Extend-A-Pour, for up to thirty days Within the chemical groups, impressions disinfected with 1% sodium hypochlorite showed more discrepancy in the dimensions when compared to the 2% glutaraldehyde disinfected group. Conclusions: UV light disinfectant can be safely used to disinfect impressions as compared to chemical disinfectants in clinical prosthodontic procedures Hydrocolloid and elastomeric impression materials must be poured within ____ so that distortion does not occur automatically mixed and via! Of setting & elasticity gag reflex when taking alginate impressions must be able reproduce! Condensation Silicones â condensation silicone impression materials can be further divided into hydrocolloid.

Materials 2 Flashcards Quizle

  1. Disinfected impressions that are sent to the dental laboratory should be labeled as such in order to prevent duplication of the disinfection protocol. Impressions must be rinsed to remove saliva, blood and debris and then disinfected. Impressions can be disinfected by immersion in any compatible disinfecting product
  2. Introduction. Alginate is the most commonly used impression material in an orthodontic practice for making diagnostic and working casts. Alginates are irreversible hydrocolloid materials that were originally developed in the 1930s (Doubleday, 1998).The main advantages of alginates are the ease of use, the low cost, their hydrophilic characteristics, and the good patient acceptability (Frey et.
  3. utes later if it does not tear, resulting in a second cast that is as accurate as the first cast or a second alginate impression. 17 Because of this property of alginate, as long as the closed-mouth tray remains wrapped in the wet.
  4. utes of making the alginate impression. 19-21 Some offices may make the alginate counter-model impression and not pour it up immediately. Instead, the impression is wrapped in a paper towel moistened with disinfectant, and placed in a plastic bag to prevent.
  5. utes delay Dehydration occurs on exposure to air leading to shrinkage. Imbibition occurs if immersed in water and disinfectants This is avoided by 1- pouring immediately 2-placing it in 100 percent humid atmosphere [humidor]or 3- wrapping in wet/disinfectant soaked.

MDA CHAPTER 46 IMPRESSION MATERIALS Flashcards Quizle

  1. utes for type 1 paste and within 15
  2. s ďƒ˜ Alginate expands when it contacts liquids.
  3. utes for type 1 paste and within 15
  4. utes may become inaccurate enough to require remaking the impression. Pour measured amount of water into a clean mixing bowl and then add powder. 1 hour. Asked by Wiki User. Impressions disinfectants and cleaners. This method is how we learned is school However it is not very practical when setting up for procedures ahead of time. what.
  5. Surface detail reproduction and dimensional accuracy of stone models: influence of disinfectant solutions and alginate impression materials. By Sandrine Berger. Effect of immersion disinfection with Perform-ID on alginate, an alginate alternative, an addition-cured silicone and resultant type III gypsum casts
  6. Multiple materials and techniques have been reported for complete denture impressions in literature. The aim of the study was to assess the trends in complete denture impression materials and techniques among general dental practitioners (GDP) an
  7. impression materials and their ability to reproduce details of soft and hard tooth tissues. The most susceptible to this damage were alginate impression materials6-8) and polyethers. It is well-known that due to the hydrophilic properties of alginates, water and a high concentration of water-soluble salts in their structure

Accuracy and dimensional stability of extended-pour and

The VSE impression was obtained using a 2 viscosity impression technique with heavy- and light-body material ( Table 1). All impressions were disinfected for 10 minutes (Impresept; 3M ESPE). After 8 hours of storage, the VSE, POE, and ALG groups were poured in Type IV dental stone (Cam-Base; Dentona AG) Impression material must not be separating from the impression tray Consider pouring your models right away if your impressions are moisture, temperature, or time sensitive Impressions sensitive to moisture content should be wrapped in a damp paper towel and placed in a sealed plastic bag if models are not poured immediatel

Elastic - Helps the impression material from cracking Adherence to the impression tray - If it comes off the tray you must redo. Adhesi8ve improves accuracy of impressions, without adhesive the shrinkage pulls the material from the walls and you get a tight impression. Inadequate adhesion leads to dislodgement and distortio An alginate impression with a stock tray was made for a preliminary cast, allowing for the fabrication of an interim acrylic resin obturator, in which the obturator bulb portion was built incrementally and adjusted. However, a digital impression was suggested as a more tolerable approach to making a definitive prosthesis for the patient Primary impressions using alginate (Orthoprint, Zhermark Inc, Eatontwon, NJ) and wax occlusal records were taken to make articulated models. The diagnostic casts were duplicated using light viscosity additional silicone impression material (Elite Model, Zhermark Inc) and the impressions were poured using dental stone (Elite Rock, Zhermark Inc)

Two alginate impressions were made of the maxillary arches on each of the 15 dried skulls (Jeltrate Plus; Dentsply Caulk). Impressions were poured with a Type IV dental stone (Jade Stone; Whip Mix Corp) with the recommended powder and liquid ratios and were spatulated in a vacuum power mixer (Whip Mix Corp) for 30 seconds Upon Inc) and the impression was poured using dental stone (Elite intraoral examination, a class II division 1 incisor relationship Rock, Zhermark Inc). Afterwards, a completed diagnostic with an anterior open bite and loss of vertical height in the preparation of abutments (Figures 3 and 4) and waxup of premaxilla were diagnosed

The introduction of intraoral scanners has enabled a digital workflow for dental prosthetic processes. The first step in the preparation of a restoration in a dental laboratory computer-aided design and computer-aided manufacturing (CAD-CAM) system is to make an impression of the mouth and pour a definitive cast Analog impression procedures use elastic impression materials poured with dental stone. This procedure is prone to inaccuracies. In addition to other advantages of digitization, the fit of CAD/CAM single crowns is better than that of analog ones, even though the digital modeling still remains problematic, especially in areas located further. Casts produced from alginate impressions must be generated immediately or within 3 hours after the impressions are removed from the patient's mouth (3). There are many contingencies so, many dentists do not pour their impressions immediately and send them to the commercial laboratories. Unde Impression material must be retained in the tray (alginate) Non aqueous elastomeric impression materials (elastomers) Should be poured up within 2 hours of impression taking lab required- ideally should be poured within an hour Hydrophilicity Hydrophilic and can produce detailed impressions in a wet field

Impression Materials - Dental Scienc

  1. alginate impressions. To avoid introducing bubbles, briefly rinse with water shortly before pouring, † Position impressions must not be exposed to solvents or solvent-containing liquids. If this product is defective within the warranty period,your exclusiv
  2. ary open mouth alginate impressions are helpful in diagnosis. Quick- setting plaster of Paris casts may be poured and mounted on a simple articulator at an approximately correct vertical relationship. Study of the result aids in visual- izing the design of the contemplated prostheses, particularly regarding the selection of the type of.
  3. Currently, there are extended-pour alginates that can keep their dimensional stability for 5 days until cast generation [14]. The possibility of storing impressions without consequent dimensional alterations would be an advantage of a material within the clinical setting, enabling the professional to conclude a procedure or send an impression t
  4. utes from taking the impression, G2 - 10.
  5. Impression Agar Poly compound Alginate silicones • Impressions must be dimensionally stable until the cast can be poured Impression should maintain Disadvantages Poor dimensional stability water by-product pour within one hour single pour Custom trays Messy paste-paste mix.

dental material questions

RDA BOARD EXAM Flashcards Chegg

final 8 Jeopardy Templat

As 3D imaging of dental models becomes more common in clinical dentistry, the need for accurate images will increase. In order for these 3D models to be of greatest benefit, they will need to be aligned to accurately represent the given presentation of the individuals they represent. This is an important step, since the acquisition of digital models results in two unrelated image files. This. Academia.edu is a platform for academics to share research papers Next, an impression of the 3D printed setup was taken and the impression poured in plaster (Figures 3B-3C). Digital impressions must be as fast as your current alginate process if your goal is.

A method for dental restoration that includes disposing a flowable and curable tooth restoration composition into an open cavity of a stent that defines contours of a final design model of a patient's teeth and includes an interproximal contact that has been thinned along an interproximal contact zone but not separated, seating the stent on the patient's teeth such that the flowable and. US8696356B2 US13/270,864 US201113270864A US8696356B2 US 8696356 B2 US8696356 B2 US 8696356B2 US 201113270864 A US201113270864 A US 201113270864A US 8696356 B2 US8696356 B2 US 869

US20120028210A1 US13/270,864 US201113270864A US2012028210A1 US 20120028210 A1 US20120028210 A1 US 20120028210A1 US 201113270864 A US201113270864 A US 201113270864A US 2012028210 ce378 - Free download as PDF File (.pdf), Text File (.txt) or read online for free. alginate impression

Air Force Manual Version 2 [8x4ed1pr0gl3]. AIR FORCE PAMPHLET 47-103 VOLUME 2 15 NOVEMBER 2005 Dental Laboratory Technolog There must be at least two differently smelling perfume oils present. The term differently smelling here covers the entire spectrum from gradual variability to total variability. One example of gradually differently smelling perfume oils would be present, for example, if perfume oil 1 radiates an orange-like scent and perfume oil 2.

The effect of pouring time on the dimensional accuracy of

October 27-28, 2017 Hilton Anatole Dallas. New Speakers Join MKS Scott Law is a wet-fingered orthodontist overseeing the clinical aspects of Smile Doctors, an orthodontist-owned orthodontic group. Pour after 20 minutes as H2 evolves to create voids if poured before • Called type 2 silicone impression FLOW of type 1 impression compound: At 37 0C - 6 % (AIPG 07) At 45 C - > 85 % 0 zz Of type 2 impression compound: At 37 0C 2 % At 45 0C 75 to 85 % z 15. Elastic Impression Materials— Agar and Alginate 16. Elastomeric Impression Materials 1. Overview of Dentistry and Dental Materials 3 2. Structure and Properties of Dental Materials 9 3. Structure and Properties of Metals and Alloys 39 4. Electrochemical Properties of Materials 56 5. Biological Properties of Dental Materials 6 1.7.1. Irreversible hydrocolloid impression materials Owing to their low cost, ease of use and sufficient wettability, alginate impression materials have been frequently used to fabricate diagnostic casts. These casts are further used to fabricate partial and complete dentures. Interim/temporary cast can also be fabricated with the help of.